Specifications of the Digital LCR Bridge Model SM8280 |
||||
|
L: 0.01uH - 200H; C: 0.1 pF- 20mF; R: 0.001Ohm - 20M Ohm; D: 0.001 - 2.0 |
||||
| Capacitance ( Test Mode: Parallel equivalent) | ||||
| Range | Resolution | Accuracy | Test Signal fo = 1KHz | |
| 200pF | 0.1 pF | ¡À2% ¡À 2 | 400mV/rms | |
| 2nF | 1 pF | ¡À1%¡À 2 | 400mV/rms | |
| 20nF | 10pF | ¡À0.5% ¡À 2 | 400 mV/rms | |
| 200 nF | 100pF | ¡À0.5% ¡À2 | 400 mV/rms | |
| 2 uF | 1nF | ¡À1% ¡À2 | 400 mV/rms | |
| Capacitance ( Test Mode: series equivalent) | ||||
| 20 uF | 10nF | ¡À1% ¡À2 | 0.4 mA/rms | |
| 200uF | 100nF | ¡À1% ¡À2 | 4mA/rms | |
| 2000uF | 1uF | ¡À2%¡À2 | 4mA/rms | |
| 20mH | 10uF | ¡À3%¡À2 | 4mA/rms | |
| Temperature coefficient:0.1%/¡æ; Dissipation factor additional error: 3D% | ||||
| Dissipation Factor | ||||
| 0- 1,999 | 200pF | 2nF<Cx<2uF | 2uF<Cx<2mF | 20mF |
| N.S. | 1%+10+2000/Cx | 2%+20+2000/Cx | N.S. | |
| Note: | ||||
| *Accuracy is ¡À(% of the reading +number of reading) | ||||
| *Cx is capacitance readout in counts | ||||
| *Accuracy is applied when Cx is from 20% to 100% of full scale range in series mode only. | ||||
| * Since the meter may test a capacitor under different conditions than that we make in factory, the values might not be identical as we do in factory, this is not due to meter error,just the test mode and test conditon may vary in different measurement conditions. | ||||
| Inductance Ls( Test mode: series equivalent) | ||||
| Range | Resolution | Accuracy | Test Signal fo=1Khz | |
| 20uH | 0.01uH | ¡À5%+4 | 4mA rms | |
| 200uF | 0.1uH | ¡À3% + 4 | 4mA rms | |
| 2mH | 1uH | ¡À2% +2 | 4mA rms | |
| 20mH | 10uH | ¡À1% + 2 | 400 uA rms | |
| 200mH | 100uH | ¡À1% + 2 | 40 uA rms | |
| 2 H | 1mH | ¡À2% + 2 | 4uA rms | |
| 20H | 10mH | ¡À2%+ 2 | 0.4uA rms | |
| 200H | 100mH | ¡À3%+ 2 | 0.04uA rms | |
| Temperature coefficient:0.1%/¡æ; Dissipation factor additional error: 3D%( Q= 1/D) | ||||
| Dissipation Factor | ||||
| 0- 1,999 | Lx < 200mH | 200mH<Lx<200H | ||
| 1% + 10 + 2000/Lx | 2%+20+2000/Lx | |||
| Note: Lx is the inductance readout in the counts. Accuracy is applied when L is from 20 to 100% of the full scale range in series mode measurement. | ||||
| Resistance Rs( test mode: series equivalent) | ||||
| Range | Resolution | Accuracy | Test Signal fo=1Khz | |
| 2 Ohm | 0.001 Ohm | ¡À1% ¡À5 | 4mA rms | |
| 20 Ohm | 0.01Ohm | ¡À1% ¡À2 | 4mA rms | |
| 200 Ohm | 0.1 Ohm | ¡À1% ¡À 2 | 4mA rms | |
| 2K Ohm | 1 Ohm | ¡À1% ¡À 2 | 400 uA rms | |
| 20 K Ohm | 10 Ohm | ¡À1% ¡À 2 | 40 uA rms | |
| 200 K Ohm | 100 Ohm | ¡À1% ¡À 2 | 4 uA rms | |
| 2M Ohm | 1 K Ohm | ¡À2% ¡À 2 | 0.4 uA rms | |
| 20 M Ohm | 10 Kohm | ¡À3% ¡À 2 | 0.04 uA rms | |