Dual Tracking
Dual tracking is provided, enabling positive and negative voltages
and currents to track from zero simultaneously when varied, providing
positive and negative outputs with the same absolute value. This
tracking function can be disabled for individual setting of positive and
negative values.
-
Simultaneous Digital
Display of Voltage and Current
Output voltage and current are indicated simultaneously on 7-segment
red LED displays, and a switch operation can be used to display the
voltage and current of any of the outputs.
-
Presetting of Voltage
and Current Value Pairs (3 points)
Three sets of frequently used voltage and currents (V-A pairs) can
be preset, thereby enabling quick setup of the power supply output. A
variable adjustment enables continuous adjustment of each output. The
output on/off time can also be preset.
-
One-Dial Control
To simplify operation, all condition settings are selected at the
push of a button, with a single rotary-encoder dial being used to set
all values. In addition, output voltage and current can be set to
resolutions of 10mV and 10mA, respectively. Normal/fast switching is
also possible.
-
Output Protection
When the output is on, if a preset switch or variable switch is
changed or the tracking switch is set to on, a protection circuit cuts
off the supply output, to prevent output of unexpected voltages and
currents (when the output protect switch is set to on).
-
Key Lock
A Key-lock function can be used to forcibly hold all setting values,
thereby preventing the inadvertent changes of values during a power
supply operation extending over long hours, or when you leave the power
supply unattended during experiments.
-
Last-One Memory
A backup function holds setting values, so that when the power is
switched on the values in effect when power was switched off are set
automatically, eliminating the need to make settings once again (except
for the output switch and protect switch which are not backed up.)
-
ON/OFF Delay Time
For a multiple-output power supply, when more than one of the
outputs are switched on or off simultaneously, the experimental device
or circuit being supplied may be influenced unexpectedly, running the
risk of damage. To prevent this, the delay time feature enables you to
turn on a given output only after a delay time, and turns this output
off this same delay time before the other outputs.
-
Natural Cooling
Thanks to an energy-saving design minimizing the temperature rise
inside the unit and to a structure with high heat exhaust efficiency,
the unit does not need a ventilation fan, thereby eliminating trouble
such as noise, vibration and absorption of dirt.
-
Rack Size Unit
Assuming the use in experimental fields and in combination with
system components, the unit has a case size which complies with the rack
specifications of EIA and JIS.