Specifications of MS8218 ( True RMS Meter)

AC Voltage/ DC Voltage + AC Voltage
Range Resolution Accuracy
40Hz - 1KHz 1KHz -10KHz 10KHz-20KHz
50 mV 0.001mV ¡À(0.5% of reading + 30digit) ¡À(1.0% of reading + 30 ) ¡À(2.5% of reading + 40)
500mV 0.01mV ¡À(0.5% of reading + 40 digits) ¡À(1.0% of reading + 30 ) ¡À(2.5% of reading + 40)
5V 0.1mV ¡À(0.5% of reading + 40 digits) ¡À(1.0% of reading + 30 ) ¡À(2.5% of reading + 40)
50V 1mV ¡À(0.5% of reading + 40 digits) ¡À(1.0% of reading + 30 ) ¡À(2.5% of reading + 40)
500V 10mV ¡À(0.5% of reading + 40 digits) ¡À(1.0% of reading + 30 ) unspecified
1,000 V 1V ¡À(0.5% of reading + 40 digits) unspecified unspecified
DC Voltage
Range Resolution Accuracy
50mV 0.001mV ¡À(0.03% of reading + 10 digits)
500 mV 0.01mV ¡À(0.03% of reading + 6 digits)
5V 0.1mV ¡À(0.03% of reading + 6 digits)
50V 1mV ¡À(0.03% of reading + 6 digits)
500v 10Mv ¡À(0.03% of reading + 6 digits)
1,000V 0.1V ¡À(0.03% of reading + 6 digits)
AC Current/DC + AC current
Range Resolution

Accuracy

40 Hz - 1 KHz 1 KHz - 10 KHz 10 K Hz - 20 KHz Voltage Drop
500 uA 0.01uA ¡À(0.75% of reading + 20 digits) ¡À(1% + 20 digits) ¡À(2% + 20 digits) 102 uV/uA
5,000uA 0.1uV ¡À(0.75% of reading + 10 digits) ¡À(1% + 20 digits) ¡À(2% + 10 digits)
50mA 1 uA ¡À(0.75% of reading + 20 digits) ¡À(1% + 10 digits) ¡À(2% + 20 digits) 1.5 mV/mA
500mA 10 mA ¡À(0.75% of reading + 10 digits) ¡À(1.5% + 10 digits) ¡À(2% + 20 digits)
5A 0.1mA ¡À(0.75% of reading + 20 digits) ¡À(1.5% + 20 digits) ¡À(2% + 20 digits)
10A 1mA ¡À(1.0% of reading + 10 digits) ¡À(1.5% + 10 digits) Unspecified 30 mV/A
Frequency Range: 40Hz - 400Hz, 40Hz- 200Hz for 600mV range
Response: Average calibrated in rms of sine wave.
Input impedance: 10M Ohms, Maximum input voltage: 1,000V DC or 700V AC
DC Current
Range Resolution

Accuracy

Volt Drop
500uA 0.01uA ¡À(0.15%+20 digits) 102uV/uA
5,000uA 0.1uA
50mA 1 uA 1.5 mV/mA
500mA 10uA
5A 0.1mA

¡À(0.5%+10 digits)

30mV/A

10A 1 mA

¡À(0.5%+10 digits)

Logic Frequency
Range Accuracy Sensitivity
5 Hz - 2 MHz ¡À(0.0006% of reading + 4 digits) Vp 2- 5V Square wave
Overload protection: 1,000Vp dc or 1,000Vp Sensitivity: 500mV rms
Linear Frequency
Range Volt/Current Range Sensitivity Accuracy
5 Hz - 200 KHz 500 mV 100mV

¡À(0.0006%+ 4 digits)

5V 0.5V
50V 4V
500V 40V
100V 400V
5,000 uA 1 mA
500 mA 100mA
Diodes Test
Range Resolution Description Test Condition
2.5V 0.1mV Display read approx forward voltage of the diodes Forward DC current approximately 1mA, Reversed DC voltage approximately 3.5V
Resistance
Range Resolution Accuracy
500 Ohm 0.01 Ohm ¡À(0.1% of reading + 10 digits)
5K Ohm 0.1 Ohm
50 K Ohm 1 Ohm
500 K Ohm 10 Ohm
5M Ohm 100 Ohm
50M Ohm 1 K Ohm ¡À(0.5% of reading + 10 digits)
Open circuit voltage :0.45V, overload protection: 1000Vp
Continuity Check
Range Resolution Accuracy Description Test condition
600 Ohm 1 Ohm < 25 Ohm Open circuit voltage: approx 1V
Overload protection: 1,000Vp dc or1,000Vp
Capacitance
Range Resolution Accuracy
50 nF 0.01nF ¡À(1.0% of reading + 5 digits)
500 nF 0.1nF
5uF 1nF
50uF 10nF
500uF 0.1uF ¡À(2.0% of reading + 5 digits)
5,000uF 1 uF
Duty Ratio
Frequency Range Duty Rayio Range Resolution Accuracy
5 Hz - 500 KHz 0% - 95 % 0.01% ¡À(10% of reading + 4 digits)