Specifications of in-Rush current Clamp-On Meter MS2108

DC Voltage

Range Resolution Accuracy
0-660mV 0.1mV ¡À0.8 % of reading ¡À 3 digit
6.6V 0.001V
66V 0.01V  ¡À1.0 % of reading  ¡À2 digits
600V 0.1V

Input impedance : 10M Ohms

Overload protection:600V DC or 600 AC RMS

AC Voltage

Range Resolution Accuracy
660mV 0.1mV ¡À 1.5 % of reading +- 10 digits
6.6V 1mV
66V 0.01V
600V 0.1V ¡À1.5 % of reading +- 10 digits
Input impedance: 10 M Ohms

Frequency Range : 40 Hz to 400 Hz

Overload protection:600V DC or 600 AC RMS

DC current

Range Resolution Accuracy
0- 66A 0.01A ¡À3.0% + 10 digits
600A 0.1A ¡À2.5% of reading +- 5 digits
Max DC 600A ¡À3.0% of reading +- 5 digits

AC current

Range Resolution Accuracy
0-66A 0.01A ¡À3.0% + 5 digits
600A 0.1A ¡À3.0% of reading +- 5 digits
Integration Time: 100 ms Max. measurement range:30A -600A,Max Input: 600A

Frequency range: 40 Hz to 400 Hz, response : True root square value.

Resistance

Range Resolution Accuracy
660 ohms 0.1 ohm +-1.2 % of reading +- 2digits
6.6 K 1 ohm
66  K 10 ohm
660 K 0.1 k ohm
6.6 M 1 k ohm
66 M 10K  Ohm +-1.20% of reading +- 5digits
Overload protection: 250V DC or RMS ac for all ranges.open circuit voltage: 0.4V

Frequency

660Hz 0.1 Hz +-1.5% of reading +-  5 digits
1 KHz 0.001K Hz
>1KHz 0.001k Hz
measurement range: 10 -1 K Hz, 1V to 10V rms. 40 Hz to 100K Hz

In-rush Current

Range Resolution Accuracy
66A 0.01A +-10 % of reading +- 1digits
660A 0.1 A

By V Range

Range

Resolution

Accuracy

660Hz 0.1 Hz +-1.5% of reading +-  5 digits
6.6 KHz 0.001K Hz
10 KHz 0.001K Hz
>10Khz 0.01Khz
Range:10 -10Khz,input impedance: 10M, input voltage range: >0.2Vrms AC Max input :600V rms AC

Capacitance

Range Resolution

Accuracy

6.6uF 0.001uF +-1.5% of reading +-  5 digits
66uF 0.01uF
660uF 0.1uF
6.6mF 0.001mF
66mF 0.01mF

Audible continuity

Buzz If continuity exits ( less than 40 Ohm), built in buzz with sound
Diode Show approx forward voltage of the diode
Power off 30 minutes after , it shuts itself off when no operation.