Specifications of True RMS Clamp-On Meter MS2026R

The best part for this meter is small in size with flash light on top. The meter does the high current reading up to 1,000A on both AC and DC

DC Voltage

Range Resolution Accuracy
0-4V 1mV ¡À0.7 % of reading ¡À 1 digit
60V 0.01V
600V 0.1V  ¡À1 % of reading  ¡À2 digits
0 - 600V 1V

Input impedance : 10M Ohms

Overload protection:600V DC or 600 AC RMS

AC Voltage

Range Resolution Accuracy
0-6V 1mV ¡À 1.0 % of reading +- 5 digits
60V 10mV
600V 0.1V
0-600V 1V ¡À1.2 % of reading +- 5 digits
Input impedance: 10 M Ohms

Frequency Range : 40 Hz to 400 Hz

Overload protection:600V DC or 600 AC RMS

AC current

Range Resolution Accuracy
0- 60A 0.01A ¡À2.5% + 5 digits
60A - 600A 0.1A ¡À2.5% of reading +- 5 digits
1000A 1A ¡À3.0% of reading +- 5 digits
Overload protection: 240A for 60 seconds Max.

Frequency range: 50 Hz to 500 Hz

Capacitance

Range Resolution Accuracy
600nF 0.1nF ¡À4.0% of reading +- 5 digits
6uF 1nF
60uF 10nF
600uF 0.1uF
1000uF 1uF

Resistance

Range Resolution Accuracy
600 ohms 0.1 ohm +-1 % of reading +- 5digits
6K 1 ohm
60K 10 ohm
600K 0.1 k ohm
6M 1 k ohm
60M 10K  Ohm +-1.20% of reading +- 5digits
Overload protection: 250V DC or rms ac for all ranges.

Frequency

40Hz 1 Hz +-0.1 % of reading +-  1 digits
600 Hz 1 Hz
6KHz 10 Hz
60KHz 100 Hz
100 KHz 100 KHz
1V to 10V rms. 40 Hz to 100K Hz

ADP

Range Resolution Accuracy
600 mV 0.1mV +-3.0 % of reading +- 5 digits
400 Hz 0.1 Hz

Audible continuity

Buzz If continuity exits ( less than 40 Ohm), built in buzz with sound
Diode Show approx forward voltage of the diode
Power off 30 minutes after , it shuts itself off when no operation.